Important!
Before installing, flush the pipes in compliance with DIN 1988.
8.1
Provide the water inlet with a separate lock-off.
8.2
Connect the pushbutton flusher to the water inlet.
8.3
Connect the flusher and the toilet bowl to a wall-installation flush pipe (internal
diameter Ø 26 mm).
8.4
Install the throttle application into the pushbutton flusher if:
• the flow pressure is greater than 5 bar
or
• water splashes over the edge of the toilet during flushing.
8.5
Make the cut-out for the sensor module (see drawing).
• The groove for the anti-twist feature must face downwards.
Top thickness max. 30 mm
8.6
Guide the sensor module (c) through the cut-out provided.
• The groove for the anti-twist feature must face downwards. When the sensor is
connected, the LED flashes at the top.
8.7
Slide the disc (b) on to the sensor module.
8.8
Use the nut (a) to fasten the sensor module.
8.9
Use the extension (d) to connect the solenoid valve (c) and the sensor module (e).
8.10 Connect the connecting line (f) to the sensor module (c).
• The LED flashes.
8.11 Connect the connecting line (f) to the power supply (to be provided by the customer).
Wire
colours
yellow
green
white
brown
red
9.

Adjusting Flow Duration

Flow duration can be adjusted with a free program available from Franke.
6
Connection
diagram
CAN-L bus
CAN-H bus
GND
Not used
+ 24 V DC