10. Setting the Signal Range

The signal range can be adjusted with a free program available from Franke.

11. Setting Hygiene Flushing

Hygiene flushing can be adjusted with a free program available from Franke.

12. Maintenance and Servicing

Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the fitting must be maintained and serviced at regular
intervals.
Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.

13. Fault Correction

Fault
Water does not flow
Water flows conti-
nuously
Water flow too weak
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Cause
– Voltage supply interrupted
– Water supply interrupted
– Sensor module faulty
– Solenoid valve faulty
– Solenoid valve dirty
– Solenoid valve faulty
– Supply pressure too low
– Water inflow not fully opened
Remedy
➯ Restore it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Check it
➯ Open it