TOOL AIR FITTINGS:
This tool uses a 3/8" N.P.T. male plug. The in-
side diameter should be .39" (9.9mm) or larger.
The fitting must be capable of discharging tool air
pressure when disconnected from the air supply.
RECOMMENDED OPERATING PRES-
SURE:
70 to 100 p.s.i. (5 to 7 bar). Select the operating
air pressure within this range for best fastener
performance.
DO NOT EXCEED 120 p.s.i. (8 bar).
4. TECHNICAL DATA
1 NOISE
A-weighted single-event sound power level
------ LWA, 1s, d 101.03 dB (SN883RH2)
------ LWA, 1s, d 96.9 dB (SN890CH2<34>)
A-weighted single-event emission sound
pressure level at work station
------ LpA, 1s, d 92.72 dB (SN883RH2)
------ LpA, 1s, d 86.5 dB (SN890CH2<34>)
These values are determined and docu-
mented in accordance to EN12549 : 1999.
2 VIBRATION
Vibration characteristic value
= 4.5 m/s
These values are determined and document-
ed in accordance to ISO 8662-11.
This value is a tool-related characteristic val-
ue and does not represent the influence to the
hand-arm-system when using the tool. An in-
fluence to the hand-arm-system when using
the tool will for example depend on the grip-
ping force, the contact pressure force, the
working direction, the adjustment of mains
supply, the workpiece, the workpiece support.
5. APPLICATIONS
∗ Floor and wall framing
∗ Subflooring
∗ Roof and wall sheathing
∗ Fencing
2
= 4.26 m/s
(SN883RH2)
2
(SN890CH2<34>)
3. AIR SUPPLY AND CON-
NECTIONS
WARNING
READ SECTION TITLED "SAFETY IN-
STRUCTIONS"
DO NOT USE ANY POWER SOURCE EXCEPT
AN AIR COMPRESSOR
The tool is designed to operate on compressed
air. Do not operate the tool on any other high-
pressure gas, combustible gases (e.g., oxygen,
acetylene, etc.) since there is the danger of an
explosion. For this reason, absolutely do not use
anything other than an air compressor to operate
the tool.
5
OPERATE WITHIN THE PROPER AIR PRES-
SURE RANGE
The tool designed to operate within an air pres-
sure range of 70 to 100 p.s.i. (5 to 7 bar).
The pressure should be adjusted to the type of
the work being fastened. The tool shall never be
operated when the operating pressure exceeds
120 p.s.i. (8 bar).
8
100