Replacing The Rinsing Pump; Replace The Aerator Rod; Storage/Overwintering - Oase ProfiClear Premium Compact-M EGC Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- EN -
8.8

Replacing the rinsing pump

The rinsing pump and capacitor box are each available as separate spare parts and can therefore be
replaced separately.
How to proceed:
 T
1. Undo the fastening device. To do this, unhook both rubber straps.
2. Loosen the union nut and disconnect the hose.
3. Take out the rinsing pump and replace.
– Disconnect the connection cable from the cable harness.
4. Fit the rinsing pump in the reverse order.
 J
5. If necessary, also replace the capacitor box.
8.9

Replace the aerator rod

How to proceed:
 U
1. Remove approx. 2/3 of the Hel-X bio-elements and keep moist. After completing the maintenance
measures, return the Hel-X bio-elements to the container.
2. Pull the aerator rod out of the clamping holder at the bottom of the container.
3. Disconnect the hose from the aerator rod and fit it onto the new aerator rod.
4. Press the new aerator rod into the clamping holder.
9

Storage/overwintering

The unit is protected from frost (e.g. stored in a garage or other enclosure)
The unit can be operated as long as the water temperature does not drop below 39.2 °F (+4 °C).
► Set the interval for time-dependent cleaning to 20 minutes to avoid damage to the rinsing device in
the event of frost.
► Install the control system in such a way that it is protected. The minimum operating temperature of
the control system is 14 °F (-10 °C).
The deeper areas of the pond have a water temperature of approx. 39.2 °F (+4 °C) in winter and are
essential for fish. Take the following measures to reduce the cooling effect on the water during
circulation by the filter system:
► Position the pump closer to the surface of the water so that only colder water closer to the surface of
the pond enters the pump.
► Insulate the return pipes from the filter system into the pond.
► Do not allow water to flow into the pond via a stream.
The unit is not protected from frost (e.g. outdoor installation)
Shut down the unit at water temperatures below 46 °F (+8 °C) or, at the latest, when freezing
temperatures are to be expected.
► Drain the unit as far as possible, clean thoroughly and check for damage.
► Empty all hoses, pipes and connections as far as possible.
► Leave the slide valves open.
► Cover the filter container to prevent the penetration of rain water.
► Protect pipes and slide valves that are in contact with water from frost.
34

Publicidad

Tabla de contenido
loading

Tabla de contenido