Aventics AS-i Instrucciones De Servicio página 71

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 169
Table 9:
Valve address assignment for 8x bus coupler
1)
AS-i data bit
1
D1.0
Sol.
14
D1.1
D1.2
D1.3
D2.0
D2.1
D2.2
D2.3
Sol.
12
Max. 4 valves with 2 solenoids
AVENTICS | AS-i | R499050017–BDL–001–AE
and then the valves with one solenoid (see Tab. 9 on page 71 and
Tab. 10 on page 72).
Observe the maximum number of valve solenoids that can
be controlled (4 or 8) depending on the bus coupler (see
Tab. 9 and Tab. 10).
Valve pos.
2
3
4
Sol.
14
Sol.
14
Sol.
14
Sol.
12
Sol.
12
Sol.
12
each
Max. 8 valves with 1 solenoid each
1) D1.0 is data bit 0 of participant 1, D2.0 data bit 0 of participant 2
Commissioning and operation
5
6
7
Sol.
14
Sol.
14
Sol.
14
71
Byte address
8
A0
A1
A2
A3
A4
A5
A6
Sol.
A7
14

Publicidad

Tabla de contenido
loading