To ignite burners using match lighting:
Open the hood.
Turn all control knobs on the control panel OFF ( O ).
Make sure the regulator is tightly connected to the LP
gas cylinder and a leak test has been performed.
Open the cylinder valve completely.
Using the match holder included with this grill, place a
match between the circular wire.
Light the match and place into lighting hole on the side
of the firebox.
Push in the far right control knob and turn to ON
When burner is lit, turn the control knob to the desired
setting.
If burner fails to light, extinguish the match then turn the
control knob OFF and wait five (5) minutes then repeat
the step.
NOTE: Place burner on high and observe flame height
which should be approximately 1 inch. If flame is too
high or too low, turn the control knobs OFF and perform
a burner flame check as described in the Maintenance
section.
To light other burners: push in and turn on the control
knob next to the lit burner to light.
Fig. 28
OPERATION
.
MATCH
HOLDER
LIGHTING
HOLE
21 - English
RESETTING THE GAS REGULATOR SAFETY
DEVICE
Since 1995, all regulators include a safety feature that
restricts gas flow in the event of a gas leak. If you turn on
the control knob before turning on the cylinder valve, you
can activate this feature. Even with all the burners turned
on high, the grill won't get hotter than 250°F to 300°F. It will
then be necessary to reset the gas regulator safety device.
To reset:
Open the hood and turn all control knobs on the
control panel OFF ( O ).
Close cylinder valve completely and disconnect the
regulator from the LP gas cylinder.
Wait 30 seconds and reconnect the regulator.
Open cylinder valve and follow igniting instructions.