Installation
Utility Connections
GAS CONNECTIONS
Connect the oven to the gas line with the proper
type of gas according to Local and National Instal-
lation Standards.
Setting Equipment for Other Types of Gas
1. Shut off the gas valve and turn off the operat-
ing switch.
2. Dismantle the gas block by means of cou-
plings.
3. Dismantle the main burner and replace the in-
jector.
4. Replace pilot injector.
5. Install the burner and gas block.
6. Check for leakage and possible loose electri-
cal connections.
7. Adjust gas pressure if necessary, See
Figure 20.
Type of
Inlet
Gas
Pressure
mbars
G25
25
G20
20
G20/G25
G20/G25
20/25
20/25
G30
30/50
G31
30/37/50
Burner
Pressure
mbars
12
8
Totally Inscrewed
Totally Inscrewed
Pressure Regulator
17
24
8
Gas Pressure
Adjustment
Figure 20
Injector
Air
Diameter
Opening
mm
mm
5,80
16
5,80
16
5,15
5,15
16
16
3,48
16
3,48
16
Pressure
Tap
Pilot
Standard
Injector
Delivery
mm
Value kW (H
2 x 0,63
46 Nat. Gas
2 x 0,63
46 Nat. Gas
2 x 0,63
2 x 0,63
46 Nat. Gas
46 Nat. Gas
2 x 0,30
46 Butane
2 x 0,30
46 Propane
)
S