INSTALLATION
a
DANGER!
Danger of breakdowns or malfunction.
• Only use the pipework specifically intended for
refrigerant R410A for the Air to Air heat pumps
installation. Never use plumbing pipes.
8.3

General installation diagram

b
WARNING!
Danger of breakdowns or malfunction.
• Observe the minimum clearences indicated in
Figure 8.1.
b
WARNING!
Danger of breakdowns or malfunction.
• The minimum assembly distance between the
indoor and outdoor units must not be less than
three meters, otherwise there are risks of mal-
function and noise from the outdoor unit.
B
A
A
G
E
F
H
E
Fig. 8.1
General diagram of the installation and the
minimum assembly distances.
8
D
B
F
C
G
D
Legend
A
Clearance to ceiling above (minimum 5 cm)
B
Height in relation to the floor (minimum 2 m)
C
Rear clearance (minimum 20 cm)
D
Side clearance connections side (minimum 30 cm)
E
Front clearance (minimum 100 cm)
F
Side clearance opposite side connections (minimum
20 cm)
G
Clearance to the front of the internal unit (minimum 10 cm)
9

Installation of the indoor unit

9.1

Selecting the clearance location

b
WARNING!
Danger of breakdowns or malfunction.
• Observe the minimum clearances indicated in
Figure 8.1.
i
NOTE
If a hole already exists in the wall or a refrigerant
pipe or condensed water pipe has already been
installed, the base plate can be mounted to adapt
to these conditions.
Recommendations:
- Install the indoor unit close to the ceiling,ensuring
minimum clearances are met.
- Choose a position site that will allow air to reach all parts
of the room evenly. Avoid beams, obstructions or lights
which would interfere with the airflow.
- Install the indoor unit at an adequate distance from chairs
or workstations in order to avoid unpleasant draughts.
- Avoid installing close heat sources.
9.2

Fixing the mounting plate

Carry out the steps described below:
• Place the mounting plate on the chosen installation point.
• Level the plate horizontally and mark the position of holes
to be made on the wall.
• Remove the plate.
WARNING!
b
Check the area where the indoor unit is to be
fitted.
• Check that there are no electricity cables, pipes
or any other services which could be damaged
when the mounting holes are drilled. If other
services are found, choose another installation
location and repeat the aforementioned steps.