Operating instructions SATAjet 3000 B RP (DIGITAL)
4.6 Round/fl at spray control
Round/flat spray control for right-handed painters
for infinitely variable adaptation of the spray fan to the object:
Turn to the left - flat spray
Turn to the right - round spray
4.7 Nozzle set
Complete, hand-checked nozzle-set, consisting of paint needle (V4A), paint
nozzle (V4A) and air cap. Mount the nozzle set tightly (use universal wrench
for the paint nozzle). Insert paint nozzle before putting in paint needle. The
air cap should be placed in a position in which the marking is on top. Use
punched hexagon socket (wrench size 12) of universal wrench for paint
nozzle. Only original SATA parts guarantee highest quality and lifetime.
When mounting foreign parts, quality reduction is possible and the SATA
warranty expires.
Nozzle sets
132357 for SATAjet 3000 B RP 1,0
132365 for SATAjet 3000 B RP 1,2
138784 for SATAjet 3000 B RP 1,2 S
132373 for SATAjet 3000 B RP 1,3
4.8 Spray distance
In order to avoid overspray and surface problems, we recommend a spray
distance of 7 - 9 inches on 29 - 35 psi between air cap and object should
be maintained in accordance with the chart below, depending on spray gun
type and material.
5. Changing the self-adjusting Seals
a) Material Side: For replacement of the self-adjusting paint needle packing the paint needle
must be removed. Insert SATA hexagon key size 4 with its cylindrical connection (Tool kit part
no. 9050) into the gun instead of the paint needle, and unscrew the packing screw from the
gun, together with compression spring and packing. Push the items, which are part of the paint
needle packing (part no. 15438: compression screw, compression spring and new packing)
onto cylindrical connection of the hollow key, and screw them tight inside the gun body. Check
paint needle for damage and reassemble.
b) Air Side: For replacing the seal retainer (pos. 133942) of the air piston rod, paint needle and
trigger must be removed first; then pull out air piston rod (pos. 86843) and unscrew the seal
retainer unit (pos. 82636) by means of the hollow key size 4. Screw in new seal retainer unit
and tighten thoroughly. Grease air piston rod slightly with SATA special grease (part no. 10009)
and insert it, then assemble trigger and paint needle.
a
132381
for SATAjet 3000 B RP 1,4
132399
for SATAjet 3000 B RP 1,6
132407
for SATAjet 3000 B RP 1,8
132415
for SATAjet 3000 B RP 2,0
132423
for SATAjet 3000 B RP 2,5
b
IX.5