The nozzle, suction pipe and flexible tube
must not be blocked, as this would also
cause the dust bag change indicator to be
triggered.
b) The handle can easily be detached from the
hose to remove blockages.
20
Figure
Open the lid by moving the locking lever in
the direction of the arrow.
21
Figure
a) Seal the dust bag by pulling the sealing strip
and then remove it.
b) Slide the new dust bag into the holder to the
stop.
!
Caution: The lid only closes with a dust bag
inserted.
Cleaning the motor protection filter
The motor protection filter should be cleaned
regularly by knocking out the dirt and rinsing.
22
Figure
Open the dust bag compartment lid (see
Figure 20).
Pull out the motor protection filter in the
direction of the arrow.
Clean the motor protection filter by tapping it.
If it is very dirty, the motor protection filter
should be rinsed.
The filter must then be left to dry for at least
24 hours.
After cleaning, slide the motor protection filter
into the vacuum cleaner and close the dust
bag compartment lid.
Replacing the micro-hygiene filter
The motor protection filter should be changed:
when starting a newpack of bags
23
Figure
Open the dust bag compartment lid (see
Figure 20).
Release the filter holder by moving the
locking lever in the direction of the arrow.
Remove the micro-hygiene filter. Insert the
new micro-hygiene filter into the vacuum
cleaner.
Reinsert the filter holder and clip into place.
Replacing the micro active carbon filter
If your vacuum cleaner is equipped with a micro
active carbon filter, this should be replaced
every six months.
24
Figure
Open the dust bag compartment lid (see
Figure 20).
Release the filter holder by moving the
locking lever in the direction of the arrow.
Remove the micro active-carbon filter.
Insert the new micro-active carbon filter.
Reinsert the filter holder and clip into place.
Replacing the Hepa filter
If your vacuum cleaner is equipped with a Hepa
filter, this should be replaced once a year.
25
Figure
Open the dust bag compartment lid (see
Figure 20).
Release the Hepa filter by moving the locking
lever in the direction of the arrow and remove
it from the vacuum cleaner.
Insert the new Hepa filter and clip into place.
If you have used the vacuum cleaner for fine
dust particles, clean the motor protection filter
and, if necessary, replace the micro active
carbon filter or Hepa filter.
Care
Always switch off the vacuum cleaner and
disconnect the power cord from the mains
before cleaning the appliance. The vacuum
cleaner and plastic accessories can be cleaned
with a commercial plastic cleaner.
!
Do not use a scourer, glass-cleaning agent
or all-purpose cleaning product. Never
immerse the vacuum cleaner in water.
The dust compartment can, if necessary, be
cleaned with a second vacuum cleaner or
simply wiped with a a dry cloth or dusting brush.
Subject to technical modifications.