STEP 1
INSTALLATION OF THE SENSOR PAD UNDER THE MATTRESS
Sensor Pad(s) 1 or 2
• Position the sensor pad as shown above. Make sure the printed side faces up. Do place any bedding between the mattress and the sensor pad.
• Secure the sensor pad cord to crib using a tie wrap. Run the cord on the floor to ensure it is out of the baby's reach.
•The sensor pad must rest on a completely flat and rigid surface.Place a 6mm (1/4'') thick plywood board to cover the full size of the crib or with
minimum dimensions of 28cm (11'') X 28cm (11'') X 6mm (2'') between the crib base and mattress,when using one sensor pad.The plywood
will push the sensor pad into the mattress and keeps the contact between the sensor pad and the mattress, should the baby move around.
Make sure the sensor pad's cord passes underneath the mattress as shown above.
• The sensor pad works with all baby bed sizes and all mattresses, except memory foam mattresses.. You will have to test your sensor pad on
STEP 13.
STRANGULATION HAZARD
the serious strangulation risk to infants and toddlers, parents and caregivers should never place the nursery unit within
3 feet (1 metre) of a crib.
STEP 2
INSTALLATION OF THE NURSERY UNIT
STEP 3
INSTALLATION OF THE PARENTS UNIT
Charger adapter
Charger adapter
socket
socket
Battery
compartment

HOW TO OPERATE YOUR ANGELCARE

Keep at
least 1m
(36 inches)
apart
.
Keep the adapter cord and the sensor pad cord out of the reach of children. Because of
Sensor pad cord
socket
Adapter socket
Sensor pad
sensitivity dial
Battery
compartment
®

MONITOR

POSITION OF SENSOR PAD UNDER MATTRESS
I sensor pad
Crib center
• Connect the long sensor pad cord into the nursery unit.
• Insert 4 AAA regular batteries (not included) into nursery unit (for battery
backup in case of power failure).
• Connect AC adapter to nursery unit and plug adapter into an electrical
outlet in the baby's room.
• After both units are properly installed you may adjust the sensor pad
sensitivity level. The sensitivity dial shows the level 1 to 5, where 1 is less
sensitive and 5 very sensitive. It is preset between level 2,5 and 3. Should
there be a false alarm, increase the sensitivity by a half level during testing
until it works perfectly for your mattress and bed size.
• Insert 4 AAA NIMH rechargeable batteries (included) into parents unit.
NEVER use regular alkaline batteries, they may explode.
• Connect AC adapter to parents unit charger and plug adapter into an
electrical outlet. Let charge for 15 continuous hours before using the
monitor for the first time.
9
2 sensor pads
(On some models)
Crib center