The reduction in driving speed and the truck-
to-truck warning can be set using the diagnos-
tic program.
The LED displays are not necessary for driv-
ing; they are used for test purposes.
The "ON" LED indicates the operating status
of the communication unit:
LED flashes green:
●
The communication unit is ready for opera-
tion.
LED red / flashes red:
●
The communication unit has not been con-
figured or there is a fault.
The display of the "STATUS" LED depends on
the operating status.
"STATUS" LED flashes red:
●
The communication unit is located within a
warning zone.
LED off:
●
No warning zone detected
Communication unit has a fault ("ON" LED
flashes red):
"STATUS" LED is permanently red:
●
Short circuit in the Namur connection
"STATUS" LED flashes red:
●
Cable break in the Namur connection
LED off:
●
Communication unit is not configured.
Communication unit up to 10/2019
The "ON" LED indicates the operating status
of the communication unit:
LED flashes green:
●
The communication unit is ready for opera-
tion.
LED red / flashes red:
●
The communication unit is signalling an er-
ror.