4) Press the screwdriver straight into the terminal until the contact opens
5) Insert connection wire into the designated terminal opening.
6) Pull out the screwdriver straight.
7) Repeat these steps for the other connection wires.
The charging station is connected to the power supply.
The charging station is set to 10 A in the delivery state. In order to adapt the
maximum current to the installed line circuit breaker, a configuration via the
DIP switches is necessary. For details, see
7.3.3

Electrical connection to special systems of AC power supply

Information
The charging station can in principle be connected to TN, TT and IT sys-
tems of AC power supply networks. Pay attention to the restrictions of your
vehicle manufacturer.
Installation manual V1.01
© EATON
completely. The angle of the screwdriver changes while pressing in.
Connections and wiring

8.1 DIP switch

settings.