8.2 Spare Parts
If replacement or accessory parts are necessary for trou-
bleshooting, these must first be checked to ensure the
same design.
f Use only spare parts and accessories that are manufac-
tured and / or approved by MENNEKES.
8.3 Unlocking the charging plug
If the unlocking function fails, the charging plug may be
mechanically locked in place in the socket panel by the
actuator. The charging plug cannot be removed and must
be unlocked manually.
Fig.: 20. Unlock the charging plug
f Open the device.
Î "5.4 Opening the device"
f Attach the red lever (2) to the square shaft of the actua-
tor (1). The red lever is attached with a cable tie close to
the actuator.
f Turn the red lever on the actuator by 90 ° clockwise.
f Pull off the charging plug.
f Remove the red lever and attach it close to the actuator
with a cable tie.
f Close the device
Î "5.9 Closing the device"
9. Taking out of service and
dismantling
Disconnect the cables
f Open the device.
Î "5.4 Opening the device"
f Disconnect supply, data, and control lines
f Route the lines through the membrane screw connec-
tion from the enclosure.
Dismantling the device
f Remove plugs and screws.
f Remove the device from the wall.
f Close the device
Î "5.9 Closing the device"
10. Storage
Proper storage can positively affect and maintain the oper-
ability of the device.
f Clean the device before storing.
f Store the device in its original packaging or by using
suitable packaging in a clean and dry place.
f Observe permissible storage conditions.
Permissible storage conditions
Storage temperature
Average temperature over
24 hours
Relative humidity
-25°C... + 40 °C
< 35 °C
max. 95 %
(non-condensing)