CONNECTING MOTOR CORD TO SWITCH ASSEMBLY
Disconnect the machine from the power source!
Insert the motor plug (A) Fig. 18B into the receptacle (B) of the
switch-to-motor cord.
ATTACHING THE TABLE TO THE SAW
1.
Remove the band saw blade.
2.
Align the two table studs (A) Fig. 19 in the bottom of the
table with the two holes in the trunnion assemblies (B).
NOTE: Confirm that the slot (C) Fig. 19 is facing toward the
front.
3.
Place an M13 flat washer on the table stud and thread the
table knob on the table stud.
4.
Repeat this process for the remaining table stud.
C
A
B
ATTACHING BLADE TO THE SAW
Disconnect the machine from the power source!
NOTE: The 14" band saw uses 93-1/2" length blades.
1.
Remove the table pin (A) Fig. 20 from the table.
2.
Open the two wheel guard doors (B) Fig. 20 and the blade
guard door (C).
3.
Confirm that the quick tension lever (D) Fig. 20 is
positioned to the left of the machine.
NOTE: Install the blade with the teeth pointing down, toward
the table.
4.
Slide the band saw blade, (teeth facing out), through the
slot (E) Fig. 20 in the band saw table.
5.
Place the blade around the two wheel assemblies (A) Fig.
21.
6.
Replace the table pin (A) Fig. 20.
7.
Close the two wheel-guard doors (B) Fig. 20 and the blade
guard door (C).
8.
Move the quick tension lever (D) Fig. 20 to the right .
9.
See the section "OPERATING CONTROLS AND
ADJUSTMENTS" to adjust the blade tension and
tracking.
TABLE INSERT
Place the table insert (A) Fig. 22 in opening of table.
NOTE: A tab (B) on the insert fits into the notch (C) in table
opening.
B
Fig. 18B
B
A
E
B
A
B
C
Fig. 19
A
C
B
15 - English
A
D
Fig. 20
Fig. 21
A