Technical Data

Max. operating pressure
Material inlet thread size
Diffuser thread size
Wetted parts material
Operating temperature range
Maximum material
temperature
Weight (cpl. incl. tip guard and
tip)
Introduction
This airless spray gun is to be used for the high pressure atomization of liquid
coating materials.
The 250 bar version is especially suitable for processing spray filler.
The 530 bar version is best suited for protective coating applications and can
be used with all pumps that can generate such a high pressure.

Using the Gun Trigger Lock

Always engage the gun's trigger lock when the gun is not in use.
1. To lock the trigger, turn the trigger safety lock up as far as it will go.
2. To unlock the trigger, turn the safety lock downwards.
AG 19
GB
25 MPa (250 bar)
3/8" NPS
7/8" NPS (G thread)
11/16" NPS (F thread)
High-grade steel, aluminum, PTFE, hard metal
5ºC to 40ºC
43ºC
680 g
1
Gun locked
(gun will not
spray)
2
Gun unlocked
(gun will
spray)
53 MPa (530 bar)
1/4" NPS