3. Specifications

3. Specifications
Specifications
Input
1)
Pressure range
Over pressure safety
Burst pressure
Resolution (max.)
1)
Pressure range
Over pressure safety
Burst pressure
Resolution (max.)
Type of pressure
Accuracy (measurement chain)
Display
Range of display
Units
Specifications
Functions via key press
Functions via Menu
Data logger
2)
Interface (serial)
2)
Analogue output
Power supply
Power consumption
Permissible
Working temperature
Air humidity
Storage temperature
Housing
Weight
Connection values
Max. voltage
Max. strength of current
Max. power
Max. effective internal capacitance nF
Max. effective internal inductance
CE conformity
EMC directive
ATEX directive
1)
In an oxygen version, a flush diaphragm model is not available. In an oxygen version model CPT62I0 is only available in gauge pressure ranges ≥ 0.25
bar with media temperatures between -10 ... +50 °C and using stainless steel or Elgiloy ® wetted parts.
2)
For the intrinsically safe version, the use of the interface and analogue output is not permitted within an explosive atmosphere.
3)
O-ring made of FKM/FPM or EPDM for flush diaphragm with integrated cooling element.
{}
Items in curved brackets are optional extras for additional price.
WIKA operating instructions, model CPH62I0
CPH62I0 hand-held indicator (complete measuring chain)
1 input for CPH62I0-S1
bar
0.1
0.16
0.25
0.4
bar
1
1.5
2
2
bar
2
2
2.4
2.4
depending on pressure range
bar
16
25
40
60
bar
80
50
80
120
bar
96
250
400
550
depending on pressure range
gauge {absolute 0.25 up to 16 bar & vacuum on request}
0.2 % FS ± 1 digit at reference temperature of 20 °C; optional: 0.1 %
Large LCD display for display of 2 values and additional information
max. -19999 up to 19999, depending on sensors used
can be selected: bar, mbar, psi, Pa, kPa, MPa, mmHg and inHg (dependent on
range)
CPH62I0 digital instrument
Min-, Max-memory, Hold, Tare, Offset-correction, Logger (Start/Stop)
Min-, Max-alarm (visual), Sealevel (barom. air pressure), Power-Off-Function,
measurement rate: 4/sec ("slow"); > 1000/sec ("fast"); > 1000/sec unfiltered ("peak-
detect") [via "peak-detect" and min-/max-memory: pressure peaks of 1.5 msec can
be detected]
- discrete value logger: up to 99 recordings incl. time via key press
- cyclic logger: automatic recording up to 10,000 values incl. time
- cycle time: selectable from 1 ... 3600 seconds
USB or RS-232 interface via special interface cable
0 ... 1 V; configurable (alternative instead of serial interface, selectable via menu)
9 V-zinc-carbon battery, alternative: 9 V rechargeable battery or mains supply
cycle time slow: < 1.6 mA, fast: < 7.0 mA, Low-Power-Logger-Fct.: < 0.3 mA
°C
-10 ... +50
% r. H. 0 ... 95 relative humidity without moisture condensation
°C
-20 ... +70
Impact-resistant ABS, membrane keyboard, transparent panels with protective leather
case
g
approx. 160
DC V
U o = 10,38
mA
I o = 93
mW
P o = 240
C o = 1240
L o negligible
2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (portable
equipment)
94/9/EC, Category 2G, Ignition protection type Ex ib IIC T4
2 inputs for CPH62I0-S2
0.6
1.0
1.6
2.5
4
5
10
10
4.8
6
12
12
100
160
250
400
200
320
500
800
800
1000
1200
1700
GB
4.0
6.0
10
17
35
35
20.5
42
42
600
1000
1200
1500
2400
3000
11