Hot Surfaces; Hazardous Materials; Suction Danger; Defects - Speck BADU Top Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 182
Safety
Before working on the electrical system, take the following
measures:
– Disconnect system from the power supply.
– Attach a warning sign: "Do not switch on! The system is
being worked on."
– Ensure that the system is free of voltage.
Check the electrical system regularly to ensure it is in proper
working condition.
Pos : 29 /T echnisc he Dokumentation/Betriebsanl eitung/Sic herheit/R estrisi ken/Heiß e Oberfl äche M otor @ 0\mod_1427781274683_370.doc x @ 26707 @ 3 @ 1
2.7.4

Hot surfaces

The electric motor can reach temperatures of up to 70 °C. There
is a risk of being burned.
Do not touch the motor during operation.
Allow the pump/unit to cool down before servicing it.
Pos : 30 /T echnisc he Dokumentation/Betriebsanl eitung/Sic herheit/R estrisi ken/Gefahrstoffe @ 0\mod_1427782200424_370.doc x @ 26722 @ 3 @ 1
2.7.5

Hazardous materials

Ensure that leaks of dangerous pumped fluids/gases are led
away without endangering people or the environment.
Decontaminate the pump completely during disassembly.
Pos : 31 /T echnisc he Dokumentation/Betriebsanl eitung/Sic herheit/R estrisi ken/Ans auggefahr @ 0\mod_1427783303305_370.doc x @ 26737 @ 3 @ 1
2.7.6

Suction danger

Ensure that the suction openings conform to current guidelines,
standards and instructions.
Pos : 33 /T echnisc he Dokumentation/Betriebsanl eitung/Sic herheit/Störungen/Störungen @ 0\mod_1427783778053_370.doc x @ 26752 @ 2 @ 1
2.8

Defects

In case of a defect, immediately switch the pump off and
remove it from operation.
Have all defects repaired immediately.
Pos : 34 /T echnisc he Dokumentation/Betriebsanl eitung/Sic herheit/Störungen/F estsi tzende Pumpe @ 0\mod_1427784418208_370.doc x @ 26767 @ @ 1
Seized pump
If a pump seizes, and is switched on several times repeatedly, the
motor can be damaged. Observe the following points:
Do not switch the pump/unit on repeatedly.
Turn motor shaft. See chapter 6.2 on page 21.
Clean pump.
Pos : 35 /T echnisc he Dokumentation/Allgemei ne Module/#### Sei tenumbruch #### @ 0\mod_1426069111812_0.doc x @ 891 @ @ 1
10 EN
10|2015

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Badu top-ak

Tabla de contenido