Preventing Material Damage; Leakage And Pipe Breakage; Dry Running; Cavitation - Speck BADU 93 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 192
Pos: 41 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Vermeidung von Schäden/Vermeidung von Sachschäden @ 0\mod_1427787266105_370.docx @ 26782 @ 2 @ 1
2.9

Preventing material damage

Pos: 42 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Vermeidung von Schäden/Undichtigkeit und Rohrleitungsbruch @ 0\mod_1427787655353_370.docx @ 26797 @ 3 @ 1
2.9.1

Leakage and pipe breakage

Vibrations and thermal expansion can cause pipes to break.
Install the pump/unit in a manner which reduces structure-
borne and airborne noise transmission. When doing so,
observe relevant regulations.
If the pipe forces are exceeded, leaks can occur at the screwed
connection or the pump itself.
Do not use the pump as a fixed point for the pipe line.
Connect pipes free of load and mount them elastically. Install
compensators if necessary.
If the pump leaks, the unit may not be operated and must be
disconnected from the mains power supply.
Pos: 44 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Vermeidung von Schäden/Trockenlauf @ 0\mod_1427789053644_370.docx @ 26812 @ 3 @ 1
2.9.2

Dry running

If run dry, mechanical seals and synthetic parts can be destroyed
within only a few seconds.
Do not allow the pump to run dry. This also applies to
checking the rotation direction.
Purge air from pump and suction line prior to start-up.
Pos: 46 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Vermeidung von Schäden/Kavitation @ 0\mod_1427790036391_370.docx @ 26832 @ 3 @ 1
2.9.3

Cavitation

Pipes which are too long increase resistance. This results in risk
of cavitation.
Ensure that the suction line does not leak.
Observe the maximum pipe length.
Only switch the pump on when the valve on the delivery side
is opened halfway.
Open the valve on the suction side completely.
Pos: 48 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Vermeidung von Schäden/Überhitzen @ 0\mod_1427790847604_370.docx @ 26847 @ 3 @ 1
2.9.4

Overheating

The following factors can result in the pump overheating:
Excessive pressure on the delivery side.
Motor overload switch set incorrectly.
Ambient temperature which is too high.
Do not operate the pump with the valves closed, minimum
flowrate 10 % of Qmax.
For pumps with a three-phase motor, install a built-in or
external overload switch and set it correctly.
04|2017
Safety
EN 11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Badu 93-ak

Tabla de contenido