Storage capacitance
Enclosure
Shock (Drop Test)
Diode Test
Continuity Check
PEAK
Temperature Sensor
Input Impedance
AC Response
AC True RMS
ACV Bandwidth
Crest Factor
Display
Out of range indication
9999
Double moulded, waterproof
6.5 feet (2 meters)
Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical
Sound signal will be enabled if the resistance is less than 35Ω (approx.),
test current <0.35mA
Captures peaks >1ms
Requires K-type thermocouple
>10MΩ VDC & >9MΩ VAC
True rms
The term stands for "Root-Mean-Square," which represents the method
of calculation of the voltage or current value. Average responding multi-
meters are calibrated to read correctly only on sine waves and they will
read inaccurately on non-sine wave or distorted signals. True rms meters
read accurately on either type of signal.
50Hz to 1kHz
≤3 at full scale up to 500V, decreasing linearly to ≤1.5 at 1000V
50,000 count backlit liquid crystal with bar graph
"OL" is displayed
98