2 Vacuum unit Bronze/Sopra 100 assembly instructions

2.1 Fitting the wall bracket

Position the holder so that there is plenty of space above and be-
low the place where the vacuum unit is to be located. Make sure
there is a minimum of 500 mm free space above the container.
Mark the positions for the four screw holes with a pen or similar.
Then select appropriate screws and, if necessary, wall plugs for
the type of wall surface to which the bracket is to be attached. Drill
the four holes for the wall bracket. The diameter of the screw holes
in the holder is 5 mm. Fit the wall bracket with the large opening
pointing upwards, see Fig. 1. Tighten the screws so that the holder
is held fi rmly in place (screws provided).

2.3 Connecting the machine

The machine is connected with the suction pipe in the uppermost position and the exhaust pipe in the
lower position.
This connection should not be glued but can be taped when the unit is serviced at a later date.
The suction pipe socket can be fi tted to two different points depending on the direction in
which you would like to install the pipe system.
To relocate the suction pipe socket, you need to do the following:
1. Release the suction pipe socket by unscrewing the four combination Torx screws with a Torx T20
or an ordinary screwdriver, Fig. 3.
2. Pull the socket out of the machine, see Fig. 4.
3. Loosen the plug blanking off the outlet to which you intend moving the suction pipe socket.
Unscrew the four combination Torx screws. Remove the blanking plug from the machine.
4. Adapt (move) the suction pipe socket to the new outlet. NB! The socket is marked "Up".
Make sure the socket is fi tted with "Up" uppermost. Fasten the socket by fi tting and tightening the
four screws, Fig. 5.
5. Fit the blanking plug to the outlet previously occupied by the suction pipe socket. Use the four
screws to hold it in place. The exhaust pipe must be fi rmly attached to the wall to ensure its connection with the socket does not loosen.
Remember that you will need to be able to turn the bent pipe in different directions to ensure a suitable pipe layout. Then connect up
the exhaust pipe and muffl er, Fig 6. Fit the central vacuum cleaner so that the exhaust pipe is as short as possible, max. 5 metres. Take
the surroundings into consideration when positioning the exhaust. For this reason, you should always fi t a muffl er.
For additional information concerning the assembly and installation of the pipe system and low-current lead, please refer to the separate
assembly instructions supplied with the pipe package.
34
Fig. 1
Fig. 3
Fig. 2
2.2 Locating the vacuum cleaner on the
wall bracket
Position the vacuum unit so that the wall bracket is directly above
the wall bracket, see Fig. 2. Lower the machine down on to the
wall bracket. Make sure the corresponding bracket on the machine
is held fi rmly in place by the wall bracket.
Fig. 4
Fig. 5
Inlet
Fig. 6
Exhaust