Energy Saving (Stand-By) - Nuova Simonelli Aurelia II 2 GR S Libro De Instrucciones Para El Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENERGY SAVING (stand-by)

The display will read:
ENERGY SAVING
This function allows the machine to enter an
active STANDBY status, where it is possible to
choose whether to switch off the machine com-
pletely or to keep it at a set pressure (lower than
working pressure).
Press
and the display will read:
ENERGY SAVING
xxx
Here it is possible to select the XXX mode
using the
keys.
The 4 operating modes are:
OFF: during STANDBY the machine is
switched off and the display reads "OFF";
STANDBY 0.10 bar: during STANDBY, the
machine maintains a pressure of 0.10 bar
and the display (set to minimum brightness)
reads "LOW POWER USE";
STANDBY 0.50 bar: during STANDBY, the
machine maintains a pressure of 0.50 bar
and the display (set to minimum brightness)
reads "LOW POWER USE";
STANDBY 0.80 bar: during STANDBY, the
machine maintains a pressure of 0.80 bar
and the display (set to minimum brightness)
reads "LOW POWER USE".
This type of operation is possible when switch-
ing the machine on/off manually using the
key and when switching the machine
on/off automatically using the ON/OFF pro-
gramming function.
If the RES key is pressed while the machine is
in one of the standby conditions (0.10 bar, 0.50
bar, 0.80 bar), the machine switches to OFF. If
the key is pressed again, the machine enters
the ON mode.
Press the
key to confirm the mode
selected from the display and go back.
Press the
key to go back without con-
firming.
SETPOINT TEMPERATURE
(AND OFFSET) (Version T3 only)
It is possible to access this function by
pressing the
key.
The
key serves to adjust the
temperatures of the boilers and units; the
key is used to confirm and pass to the
next value. When the last unit has been con-
firmed, the function returns to the main menu.
Pressing the
key moves to the next
value to be adjusted; any changes made will
not be saved.
SETP G1: Unit 1 temperature
SETP C1: Boiler 1 temperature
SETP G2: Unit 2 temperature
SETP C2: Boiler 2 temperature
SETP G3: Unit 3 temperature
SETP C3: Boiler 3 temperature
SETP G4: Unit 4 temperature
SETP C4: Boiler 4 temperature
OFFSET ADJUSTMENT
When the display reads:
SETPOINT TEMP
Holding down the
one long coffee keys
for the first and second units together for a
few seconds will open the OFFSET function.
The
keys serve to adjust
the OFFSET of the various unit boilers.
The
key confirms and passes to the
next value
When the last unit has been confirmed, the
function returns to the main menu
Pressing the
key passes to the
adjustment of the next value; any changes
made will not be saved.
OFFS. G1: Group 1 offset
OFFS. C1: Boiler 1 offset
OFFS. G2: Group 2 offset
OFFS. C2: Boiler 2 offset
OFFS. G3: Group 3 offset
OFFS. C3: Boiler 3 offset
OFFS. G4: Group 4 offset
OFFS. C4: Boiler 4 offset
CUP-WARMER PROGRAMMING
(If installed on the machine)
The display will read:
CUPWARMER PROG.
Pressing
will open the submenu.
Single Cup Warmer
The display will read:
CUPWARMER PROG.
Pressing
will cause the display to
read, for example:
65

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aurelia ii 2 gr vAurelia ii 2 gr digitAurelia ii 2 gr t3Aurelia ii 3 gr sAurelia ii 3 gr vAurelia ii 3 gr digit ... Mostrar todo

Tabla de contenido