Caution - Warning
Before doing any work, cut off the mains
electricity supply.
The manufacturer has tested the appliance
with its own mains gas, identifi ed by the sticker
applied to the nameplate.
If the type of gas to be connected is diff erent
from that used for testing, proceed as follows.
Turn off the gas supply tap (A).
1)
Disconnect the electricity supply.
2)
Replace the burner nozzle (see page 15).
3)
Replace the pilot light injector (see page 16).
4)
Adjust the minimum setting on the gas con-
5)
trol valves (see page 13-14).
If necessary, adjust the burner primary air (see
6)
page 14).
Remove the sticker from the nameplate and
7)
apply the new one to identify the gas being
used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
Important
GB
Before it is put into service, the system must
be tested to check the operating conditions
of every single component and identify any
malfunctions. In this stage, it is important to
check that all health and safety requirements
have been complied with in full.
To test the system, make the following checks:
Turn on the gas supply tap and check that the
1)
connections are right;
Check that the mains gas is the same as that
2)
used for commissioning of the appliance,
and carry out the conversion procedure if
necessary (see page12).
Check that the plate, top and oven burners
3)
are lighting and burning correctly;
3320090_inst_GB_rev.1
CONVERSION OF GAS SUPPLY
TESTING OF THE APPLIANCE
4)
5)
6)
7)
After testing, if necessary instruct the user in all
the skills necessary for putting the appliance
into operation in conditions of safety, in accor-
dance with legal requirements
- 12 -
A
Check the gas pressure and fl ow-rate at
minimum and maximum settings and adjust if
necessary (see page 6;
Check that the safety thermocouple is wor-
king correctly;
Check that there are no gas leaks;
Check that the nameplates specify the correct
gas for the country of use.
ENGLISH