Gas Connection; Connection Of Fume Exhaust Vent - Angelo Po 0N0TPG Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Important
Those authorised to carry out this operation
must have experience acquired and certifi ed
in the specifi c sector, must make the connec-
tion to the proper standards, and must com-
ply with all the relevant regulations and legi-
slation. Once the connection has been made,
before the appliance is put into operation a
general check must be made to ensure there
are no gas leaks.
make the connection, connect the mains line to
the appliance's connection pipe, fi tting a shut-
off tape (A) , to allow the gas supply to be cut
off when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible posi-
tion and its status (on or off ) must be obvious
at a glance.
GB
Important
Make the connection in compliance with the
relevant legal requirements, using appro-
priate and recommended materials.
Position the appliance
1)
underneath the hood (A)
(see diagram).
Important
The gas supply tap (A) must
open automatically when
the fan of the extraction sy-
stem is switched on.
3320090_inst_GB_rev.1

GAS CONNECTION

CONNECTION OF FUME EXHAUST VENT

A
- 10 -
A
Important
The gas supply pipe must comply with the
national requirements in force and must be
periodically examined and replaced if neces-
sary.
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
A
ENGLISH

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0t0tpg1n0tpg1t0tpg1n0tpgf1t0tpgf

Tabla de contenido