Faults
Smell of gas
The pilot light does not
ignite
The pilot light goes out
GB
The fl ame is yellow
Burner control knob is stiff
3320090_ut_GB_rev.1

FAULT

TROUBLESHOOTING

Per qualsiasi esigenza rivolgersi alle agenzie
o alla sede centrale Angelo Po i cui riferimen-
ti sono riportati nella sezione contatti del sito
internet http:// www.angelopo.com.
Causes
Occasional leak because
fl ame has gone out.
The spark ignition devices
are not working
Air in pipelines due to long
period out of use
The thermocouple has not
warmed up enough
Burner dirty, heat exchange
pipes clogged, condensation
drips
Gas control valve
malfunction
- 12 -
Importante
Important
Important
Wichitig
Importante
Remedies
Turn off the gas supply tap and
ventilate the room
Check that the ignition devices
are in good working order.
Light by hand with a naked light.
Important
Contact the after-sales service.
Make more attempts to light the
fl ame
Make more attempts to light the
fl ame
Important
Contact the after-sales service.
Important
Contact the after-sales service.