3.5
Setting parameters
To set the parameters with „welder" rights:
Press the adjusting knob (4) for a long time (about 3 sec.) until P001 blinks in the upper
display (2).
Use the adjusting knob (4) to select the desired parameter P001 to P009. If this value must
be adjusted or displayed, briefly press the adjusting knob (4). The (default) value blinks in the
lower display (9).
Use the adjusting knob (4) to set the value, and press the adjusting knob (4) briefly again.
Then the parameter blinks again in the upper display (2).
To leave the menu, press the release button (10). The values are stored.
How to set parameters with „master" rights:
Press the adjusting knob (4) for an extended time (about 6 sec.). First the parameter P001
blinks in the upper display (2). Then „CodE", and the line blinks in the first place in the lower
display (9).
Then use the adjusting knob (4) to enter the code, and briefly press the adjusting knob (4)
(code = 8001 – during first use the code can be changed as desired through parameter P100).
Use the adjusting knob (4) to select the desired parameter, P101 to P114. If this value must
be adjusted or displayed, briefly press the adjusting knob (4). The (default) value blinks in the
lower display (9).
Use the adjusting knob (4) to set the value, and press the adjusting knob (4) briefly again.
Then the parameter blinks again in the upper display (2).
To leave the menu, press the release button (10). The values are stored.
Parameter
name
P001
P002*
P003
P004
P005
P006
P007
P008
P009
P101
P102
P103
P104
P105
P106
P107
P100
* P002 - Power saving function:
0 - none,
1 - when the miller is running the heating element will be switched off,
2 - when the hydraulic motor is running the heating element will be switched off,
3 - when t4 is running the heating element will be switched off.
38
Description
Remaining energy saver time
Power saving function active
Heating plate temperature offset 5
Pmax for cutting
Target pressure
Target temperature
Timer T1 target value
Timer T4 target value
Pstart for cutting
Deviation for repumping
Lifting time after cutting
Set temperature (min)
Set temperature (max)
Button lock (yes/no)
Lifting pressure
Full runtime until buzzer goes on 50
Change code
default Unit
99
min
0
°C
20
bar
1/10 bar
210
°C
45
sec
6
min
10
bar
5
%
10
1/10 sec 0
160
°C
270
°C
5
sed
135
bar
1/10 sec 0
8001
ENGLISH
min
max
Rights
0
99
Welder
0
3
Welder
-25
25
Welder
10
50
Welder
Welder
P103 P104
Welder
1
1500
Welder
1
99
Welder
0
P004
Welder
1
50
Master
100
Master
0
300
Master
0
300
Master
0
50
Master
10
160
Master
200
Master
Master