Using The Inverter; Status Indications - Dometic SINEPOWER MSI 2312T Instrucciones De Montaje Y De Uso

Convertidor de ondas seno
Ocultar thumbs Ver también para SINEPOWER MSI 2312T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
SinePower
10

Using the inverter

10.1
Switching on the inverter
➤ Set the main switch (fig. 5 3, page 4) of the inverter to the "ON" position.
Set the On/Off switch to "OFF" to switch off.
➤ The inverter performs a self-test.
During the self-test, the built-in speaker emits tones and the LED flashes.
✓ After the self-test is completed successfully, the LED lights up green (fig. 5 2,
page 4).
10.2

Status indications

The LED (fig. 5 2, page 4) shows the operating condition of the inverter.
Display
Green, constantly lit
Green, slow flash
Orange, quick flash
Orange, slow flash
Red, double flash
Red, quick flash
Red, slow flash
Red, constantly lit
Red, slow flash + double flash
The inverter switches off if:
• the battery voltage drops below 10 V (12 Vg connection) or 20 V (24 Vg
connection),
• the battery voltage exceeds 16 V (12 Vg connection) or 32 V (24 Vg
connection),
• the inverter overheats.
➤ If this happens, shut down the inverter with the main switch (fig. 5 3, page 4).
EN
Input voltage
Normal mode
Energy-saving mode
Input voltage too high
Input voltage too low
Inverter overheated
Overvoltage
Undervoltage
Overload
Fan fault
Using the inverter
23

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sinepower msi 2324tSinepower msi 3512tSinepower msi 3524t

Tabla de contenido