RS-232C external control
By connecting a computer to the RS-232C terminal, you can control the projector. Use a reverse connection cable as the RS-
232C connection cable.
The commands to control the projector and the response data against the received commands are explained here.
For further information, please consult the dealer where you purchased your projector or consult the Service Center.
1. Communication Specifications
The communication specifications are as follows:
Baud rate
9600bps / 19200bps*
Data length
8 bits
Parity
None
Stop bit
1 bit
Flow control
None
* Factory set value. To change the value, refer to "Setting and Adjusting Other Functions (OPTIONS)" on page 54.
2. Command Format
2-1. Command data format (from the computer to the projector)
When sending a control command, use the following data format.
Header
ID
SP
Header: Designates the head of data and the kind of data.
"!" (21h): Control command to the projector
"?" (3Fh): Query to the projector (Asking command)
ID:
"1" (fixed)
SP:
Designates the delimiter for ID, Command, and Parameter. (20h)
CR:
Designates the terminal of the data. (0Dh)
* [
] is not necessary when Asking command.
2-2. Response data format (from the projector to the computer)
Upon executing the received control command, the projector sends back the following response data to the computer.
Header
ID
SP
Header: Designates the head of data.
"@" (40h): Fetches data from the projector.
ID:
"1" (fixed)
SP:
Designates the delimiter for ID, Command, and Parameter (20h)
Normal Termination Status: "0" (30h)
CR:
Designates the terminal of the data (0Dh)
74
Command
SP
Parameter
Normal Termination Status
CR
SP
Parameter
CR