STA-RITE INTELLIFLO VSF 5PXF-VSF Guia De Inicio Rapido página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
INTELLIFLO VSF PUMP MENUS (CONTINUED)
MENU TREE
CONTINUED FROM
PREVIOUS PAGE
EXT CONTROL
FEATURES
PRIMING
Max Priming Duration
THERMAL MODE
Disabled/Enabled
Pump Temperature
P-QSG-VSF - Rev.November 2017
Program 1
Enabled - Default
Pump Off
Program 2
Enabled - Default
Pump Off
Program 3
Enabled - Default
Pump Off
Program 4
Enabled - Default
Pump Off
Time Out
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Quick Clean
Type (Speed / Flow)
Set Speed or Flow (450-3450 RPM or 5.5-38 m³/h)
Quick Clean Duration (1 min. to 10 hrs.) Default: 10 minutes
Disabled / Enabled - Default: Enabled
Disabled/Enabled
Set Speed (2400-3450 RPM) Default: 3450 RPM
Priming Speed
(1 min. to 30 min.) Default: 11 minutes
(1 - 10) Default: 5
Priming Range
(1 sec. to 10 min.) Default: 20 seconds
Priming Delay
Enabled / Disabled - Default: Enabled
Loss of Prime
Disabled / Enabled - Default: Enabled
Set Type
Speed - Default: Speed
Flow
Set Speed/Flow
Set Speed (450-3450 RPM) Default 1000 RPM
Set Flow (5.5 - 38 m³/h) Default: 11 m³/h
40° F - 50° F (4.4° C through 10° C) Default: 40° F (4.4° C)
Type (Speed / Flow) Default: Speed
Set Speed or Flow - Default: 750 RPM
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
Type (Speed / Flow) Default: Speed
Set Speed or Flow - Default: 1500 RPM
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
Type (Speed / Flow) Default: Speed
Set Speed or Flow - Default: 2350 RPM
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
Type (Speed / Flow) Default: Speed
Set Speed or Flow - Default: 3110 RPM
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
INTELLIFLO VSF - QUICK START GUIDE
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Intelliflo vsf wfl-vsf

Tabla de contenido