On these machines there are two different fi lters; one pre-fi lter before the vacuum motor and one exhaust fi lter.
There are two different types of exhaust fi lters available to these machines, HEPA-fi lter and a standard exhaust fi lter. The HEPA-fi lter
(High Effi ciency Particulate Air filter) offers better fi ltration capacity then the standard exhaust fi lter. The exhaust fi lters catches any
dirt that may escape from the dust bag, or motor pre fi lter. Replace the fi lter every fourth time that the dust bag is changed (more
often in very dusty applications). The exhaust fi lters are located at the front side of the machine just above the brush base.
The HEPA fi lter can not be cleaned or washed clean. When the HEPA-fi lter is clogged it must be replaced.
1
3
10
823 0102 000 Instruction for use GU 305, GU 355, GU 355 DUAL, GU 455 DUAL EU 1.indd 10
823 0102 000 Instruction for use GU 305, GU 355, GU 355 DUAL, GU 455 DUAL EU 1.indd 10

CHANGING OR CLEANING OF THE BRUSH

3
6
FILTERS - type of fi lter may vary from different models
CHANGING THE HEPA-FILTER
2
4
Unplug the power cord from the electrical outlet.
1.
Release the brush roller by unlocking the bearing
2.
block. Push the button backwards left towards the
unlocking symbol at the brush housing.
Grasp at the bearing block and pull it out from the
3.
brush housing.
Remove the used brush.
4.
Replace the used brush roller with a new one, or
5.
clean and remove all debris from the present brush.
Slide back the brush into the the fi xed bearing block
6.
in the brush house.
Push the bearing block in its position. Lock it by
7.
turning clockwise.
Always disconnect the power cord before
performing any machine maintenance.
1. Disconnect the power cord from the electrical outlet.
Push the Filter Cover Latch (19) downwards so that the
cover (18) is released. Remove the fi lter cover from cleaner.
2. Grasp at the fi lter frame and remove the used and dirty
HEPA-fi lter
3. Grasp at the fi lter frame and then insert the new HEPA fi lter
to the cleaner by pushing it in place. Never touch the fi lter
media at a HEPA-fi lter! Doing so may cause a loss of
performance of the HEPA-fi lter).
4. Snap the Filter Cover back in place at the cleaner.
IMPORTANT!
Never operate the cleaner without the HEPA-Filter in place in the
machine. Note! These machines are not designed for picking
up hazardous - i.e. poisonous dust!