5.3 Quick setup parameter description
Name
Motor Nom Voltage
Motor Nom Freq
Motor Nom Current
Current Limit
Motor Cos Phi
Motor Nom Power
Pump Selection
Min Freq Reference
Max Freq Reference
Acceleration time
Deceleration time
PV modules type
Module MP Voltage
Series Modules No.
Output Sinus Filter
Advanced Level PW
Digitial inputs
DI1
DI2
DI3
DI4
DI5
DI6
The User settings column is left blank to allow users
to write down their own input settings.
After modifying the parameters in the table
above, the inverter needs to be stopped
Note
and started again to update the
parameters.
No record is made of undervoltage fault
Note
caused by insufficient power due to low
sunlight intensity.
Description
Motor rated voltage
Motor rated frequency
Motor rated current
Maximum current from drive
Motor power factor
Motor rated power
Grundfos pump family
Lower frequency
Target frequency
Initial ramp time
Final ramp time
Solar panel type
Vmp maximum power point voltage
Number of solar panels in series
Select if sine-wave filter is used or not
Password for advanced menu and
service
Description
Start/stop
Tank level switch
Well level switch
Flow switch
Flow meter (pulsating)
AC operation
Factory setting
User setting
380
50
Size-dependent
Size-dependent
Size-dependent
Size-dependent
SP
30
50
3
3
SW260
31, 4 V
18
No
0
15