8.5 Operation
Faults of electronic devices due to electromagnetic fields
Electromagnetic fields are created during the operation of pumps with fre-
quency converter. Interference of electronic devices may be the result. The
result may be a device malfunction, which can result in damage to the health or
even death, i.e. of persons carrying implanted active or passive medical devices.
Therefore, during operation the presence of any persons i.e. with cardiac pace-
makers in the vicinity of the unit/pump should be prohibited. With magnetic or
electronic data media, the loss of data is possible.
8.6 Decommissioning
The pump must be decommissioned before conducting maintenance, repair or
dismantling work.
DANGER! Risk of fatal injury!
An electric shock may occur when working on electrical equipment.
• Have work on the electrical part of the pump carried out only by a qualified
electrician as a basic principle.
• Before starting any maintenance and repair work, disconnect the pump
from the power supply, and make sure it cannot be switched back on by
unauthorised persons.
• Work on the module may only be started once 5 minutes have passed, due
to the dangerous residual contact voltage (capacitors)
• Check to ensure that all connections (including potential-free contacts) are
voltage-free.
• The pump may still be live even in voltage-free state. The drive rotor
induces a dangerous contact voltage at the motor contacts.
Close the check valves in front of and behind the pump.
WARNING! Risk of burns!
Touching the pump can cause burns!
Depending on the operating status of the pump or unit (fluid temperature),
the entire pump can become very hot.
Allow the unit and pump to cool down to room temperature.

9 Maintenance/service

All servicing should be performed by an authorized service representative!
These pumps are maintenance free, self-lubricated by the system fluid, and
have no seals to leak or couplings to break.
Before carrying out maintenance / cleaning and repair work, observe Chapters
8.5 "Operation" and 8.6 "Decommissioning".
The safety instructions in Chapter 2.6 and Chapter 7 must be complied with.
After completing maintenance and repair work, install and connect the pump
according to Chapter 7 "Installation and electrical connection". Switch on the
pump according to Chapter 8 "Commissioning".
34
Subject to technical alterations!
WILO SE 03/2016