5.8 Power level selection

When heating workpieces with an induction heater, the most of the heat will be generated
in the bore and then transferred through the workpiece. Slow heating ensures that
the workpiece expands more evenly, thereby preventing damage. The large variety of
workpieces precudes the possibility of providing a speciic power level setting for each type.
Instead, the following guidelines are provided:
For sensitive workpieces, with a combination of different materials (such as
aluminum, brass), do not exceed 50% power.
When using accessory smaller yoke, never exceed 50% power.

6. Safety features

The TIH L MB is equipped with the following safety features:
Automatic overheating protection.
Automatic current control.
Over-current circuit breaker.
In the TEMP MODE the heater will switch off if the temperature probe does not
register a temperature increase of 1 °C (1.8 °F) every 1 minute (1.00 minute).
To increase the interval to 2 minutes (2.00 minute). press MODE and DOWN at the
same time.
Flashing warning light indicates ongoing heating process in the heaters TIH L 44 MB
and TIH L 77 MB.

7. Troubleshooting

Display
Fault
E03E
Overheated coil
E05E
Temperature increase of less
than 1 °C (1.8 °F) every
1 minute (or every 2 minutes)
E06E
Temperature probe not
connected (or defective) or
excessive temperature drop
E10E
Electronics communication
problem
E11E
Electronics communication
problem
E12E
Electronics communication
problem
SKF TIH L MB
Action
Wait until the induction coil cools. Switch
the heater OFF and then back ON
Check the temperature probe
connection. If the connection is OK,
select the 2 minutes interval as
described in section 6 or operate the
heater in TIME MODE
Check the temperature probe
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair