KPS-PA20 MINI • Digital clamp meter
The buzzer may or may not sounds if the resistance of a circuit under test
is between 60Ω to 120Ω. The buzzer does not sound if the resistance of a
circuit under test is higher than 120Ω.
9.

GENERAL SPECIFICATIONS

• Maximum voltage including transient overvoltage between any
• terminals and grounding: CAT III 600VDC or 600V AC peak
• Display: LCD screen, max reading 3999
• Measurement principle: Double integrated A/D converter
• Range mode: Auto range or manual range
• Measurement Speed: (2.5~3 times)/second
• Unit display: Sign
• Polarity Display: -
• HOLD: Display 'H'
• Low Battery indication: Display '
• Power supply: DC1.5V size AAA Х3 batteries
• Dimensions: 208mm×78mm×35mm
• Weight: <340g (including batteries)
• Max. Jaw Size: 26mm diameter
• Operating: 5ºC~35ºC
• Storage: -10ºC~50ºC

10. AUTO POWER OFF

To preserve battery life, the Meter automatically turns off if you do not turn the
rotary switch or press any button for around 15 minutes. The Meter can be
activated by pressing SEL button

11. REPLACE BATTERY

To avoid possible electric shock, disconnect the test leads from the circuit
under test before replace the battery. Use always the same battery type.
Make sure the transformer jaw and the test leads are disconnected from the
circuit being tested before opening the case bottom. Check that the batteries
have been installed and the battery cover has been screwed before use. Re-
WARNING
'
WARNING