APPLIANCE DESCRIPTION
Sturdy stainless steel structure with 4 adjustable feet that
can be adjusted in height. External coating made in 18/10
chromium-nickel steel. The special steel plate has a smooth or
ribbed surface and pyroceram plates all equipped with side
and back steel splashguards. It is also fi tted with a stainless
steel gravy collection tray. The steel plates are heated by
armoured heating elements whilst the pyroceram tops are
heated by infrared heating elements.
PREPARATION
Before initialising operation, remove all packaging. A
few pieces are protected by adhesive fi lm, remove these
carefully.
If some glue remains on the surface, clean with suitable
substances, for example petrol, never use abrasive
substances. Assemble the feet of the appliance, the appliance
must be levelled; small levelling adjustments may be made
by regulating the feet. The main switch or the socket must be
close to the appliance and with easy access.
The appliance should be installed under a range hood for
fast steam evacuation. Install the appliance at a minimum
distance of 5 cm from the wall when it does not resist
temperatures up to 150°C (see fi g. 1).
If the appliance is to be installed close to walls, dividing
walls, cabinets, decorative walls, etc., we recommend these
parts are coated with heat-refl ecting materials; if not, they
must be coated with heat-refl ecting material with a proper
thermal insulation and great attention must be paid to the
regulations relevant to fi re prevention.
Room ventilation
The room where the appliance is installed, must be fi tted
with air intakes to guarantee the correct operation of the unit
and air exchange.
The air intakes must have proper dimensions, be protected
by grids and they must be positioned free from obstructions.
(See Fig. 2 – Fig. 3).
Caution – Warning
Do not install the appliance close to other units that can
reach high temperature: the electrical components might
be damaged.
During installation, make sure the air suction and
evacuation ways are free from any obstacles.
INSTALLATION
The appliance must be put in operation and serviced by a
qualifi ed person.
All the installation works must be carried out according to
the regulations in force. The manufacturer declines any
responsibility in the event of wrong operation due to an
Manuale_FRYTOP_elettrico_31877000_21_01_2009.indd 24
Manuale_FRYTOP_elettrico_31877000_21_01_2009.indd 24
ENGLISH

INSTALLATION INSTRUCTIONS

improper, or non compliant installation.
Warning!
Disconnect mains before any intervention.
According to the international provisions, during the
assembly of the appliance, place before the appliance
itself, a device allowing the disconnection of the unit
from the mains circuit in an omnipolar way; this device
must have an opening of contacts of at least 3 mm.
Attention!
The yellow-green ground cable must never be broken.
Connect the appliance to the mains as shown (see Fig.4 –
Fig.5):
1) install, if not present, an isolator switch (A) close to the
2) Open, if present, the doors (B) and loosen the screws (C)
3) Connect the isolator switch (A) to the terminal board (H)
4) Pass the cable through the passage and tighten the cable
Unipotenzial
The appliance must be connected to a unipotential system.
The connection terminal is positioned close to the supply
cable input.
It is marked by the symbol:
Attention!
The manufacturer is not responsible and will not
reimburse, under guarantee, damages due to improper
installation and installation which does not conform with
these instructions.
Important
Before putting in operation, test the equipment to
24
ELECTRICAL CONNECTION
appliance with an overcurrent trip and earth-leakage
contact breaker.
to disassemble the panel (D).
as shown in the fi gures and in the electrical diagrams
at the end of the manual. The chosen connection cable
must have features similar to the H07RN-F type with
an operating temperature of at least 80°C and have a
section suitable to the unit (see technical data on the
tables).
stopper, connect the conductors in their corresponding
position to the terminal board and fi x them. The yellow-
green ground conductor must be longer than the others
so that in the event that the cable stopper breaks, it
disconnects itself after the voltage cables.