Startup; Check Connections; Turning On The System; Check Output Values - Balluff BTL5-S1 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL5-S1 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-S1_ _-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Transducer - Rod Style
5

Startup

5.1

Check connections

Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the con-
nections carefully.
5.2

Turning on the system

Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no hazards
could result from these situations.
5.3

Check output values

After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end posi-
tion of the magnet in manual
mode. If values other* than those
present before the replacement or
repair are found, a correction
should be made.
* Transducers are subject to modifi-
cation or manufacturing tolerances.
6

Versions (indicated on product label)

Type: BTL5-S102-M0450-B-DEXA -K05
Supply voltage 1 = DC 24 V
Ordering example: BTL5-S102-M0450-B-DEXA-SA_ _ _-K05
Special version (optional, no effect on Ex properties)
english
10
5.4

Check functionality

The functionality of the transducer
system and all its associated
components should be regularly
checked and recorded.
5.5

Fault conditions

When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.

5.6 Maintenance

The measuring principle of the
transducer makes it mainte-
nance- and wear-free. The op-
erator is responsible for regularly
checking for signs of damage or
malfunction. If any damage or
wear is found, the transducer
must be immediately taken out
of operation.
Cable 5 m, radial
Cable 5 m, axial
-KA05
Rod end: A = float stop
Rod style,
Mounting: B = metric thread M18×1.5
Nom. length (4-digit), M = metric, in mm
Resolution:
2 = 5 µm
Code:
24 Bit
0 = binär, steigend
2 = binär, fallend
25 Bit
6 = binär, steigend
8 = binär, fallend
Ordering code: BTL_ _ _ _
B = short end
Z = thread 3/4"-16UNF
3 = 10 µm 4 = 20 µm
5 = 40 µm
1 = Gray, steigend
3 = Gray, fallend
7 = Gray, steigend
9 = Gray, fallend
Ignition Class "d"
Flameproof enclosure

5.7 Repair

For reasons of safety the trans-
ducer is not user-serviceable.
Repairs to the transducer or the
connection cable are to be per-
formed only by service techni-
cians from Balluff GmbH.
The transducer's housing and
cable fitting may not be opened
or loosened! This is why the fol-
lowing warnings are affixed over
the gap in the housing and on
the cable fitting:
8 = 50 µm

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl5-s1b-m-b/z-dex-k serieBtl5-s1b-m-b/z-dex-ka serie

Tabla de contenido