Troubleshooting; Technical Specifications - Vortice ARIANTE ACQUA BREEZE Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH

Troubleshooting

Problem
No fan rotation when powered on
Unusual vibration sound
Sonic Cloud not working
The Sonic Cloud mist has an unusual
scent

Technical specifications

Rated Voltage / Rated frequency
Power Consumption
Max Mist Volume
Water tank capacity
Packing size
Weight
Cause
1. Fan is in fanless mode
2. Incoming voltage is too low
3. Motor spindle is stuck
1. Loose rear grill
2. Loose fan blade
3. Dirty fan blade
4. Fan blade imbalance
1. Water sensor stuck
1. The water tank interior is not clean
120 V / 60 Hz
90 W
280 ml/h
3.1 l
660 mm x 330 mm x 450 mm
6,9 kg
Solution
1. Press the power button twice when
turning the unit on to activate the
fan motor.
2. Try another power outlet
3. Unplug the unit, remove the front
grill, clean the spindle, and attempt
to loosen it manually
1. Check that the rear grill lock is secu-
rely fastened
2. Check the fan blade is properly se-
cured
3. Clean fan blade
4. Rotate the fan blade 180ºon the
spindle
1. Check the receptacle of the water
tank is clean and free of obstruc-
tions by following the maintenance
instructions
1. Clean the inside of the water tank
by filling it with water and a gentle
detergent, rinsing it out, and letting
it air dry.