SPECIFICATIONS

Starting Wattage . . . . . . . . . . . . . . . . . .5,200 watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . .3,500 watts
AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . .29.16 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . .14.58 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity. . . . . . . . 4 U.S. gallons (15.14 l)
Shipping Weight . . . . . . . . . . . . . . . 130 lbs. (59 kg)
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure
that all periodic maintenance tasks are completed on a
timely basis; that all discrepancies are corrected; and
that the unit is kept clean and properly stored. NEVER
operate a damaged or defective generator.
NOTE: Should you have questions about replacing
components on your Briggs & Stratton generator,
please contact your nearest service center for
assistance.

Engine Maintenance

See engine operator's manual for instructions.
Avoid prolonged or repeated skin contact with used
motor oil.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN.
DON'T POLLUTE. CONSERVE
RESOURCES. RETURN USED OIL TO
COLLECTION CENTERS.
3500 Watt Portable Generator
CAUTION
www.mymowerparts.com

Generator Maintenance

Generator maintenance consists of keeping the unit
clean and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with
snow, leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean
generator. Water can enter engine fuel system and
cause problems. In addition, if water enters generator
through cooling air slots, some of the water will be
retained in voids and cracks of the rotor and stator
winding insulation. Water and dirt buildup on the
generator internal windings will eventually decrease
the insulation resistance of these windings.
WARNING
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.
CAUTION
Improper treatment of generator can damage it and
shorten its life.
• DO NOT expose generator to excessive moisture, dust,
dirt, or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen caked on dirt or
oil.
• Use a vacuum cleaner to pick up loose dirt and
debris.
• Inspect cooling air slots and opening on generator.
These openings must be kept clean and
unobstructed.
12