Anleitung HGG 350 8-sprachig
GB
Maintenance
Always first unplug the heater
before any maintenance or
repairs.
Disconnect the gas hose from
the gas cylinder.
Regularly check that the gas
hose and its screw
connections are sealed. Only
original replacement parts and
hoses must be used. Hoses
must meet the specifications in
DIN 4815 Section 2.
Adjustment of the ignition
electrode should be checked
as shown in the adjacent
diagram.
Be sure to keep the safety
thermostat connection and the
thermoelement connections
clean. The connections may
become oxidized due to the
low electrical current flow,
which may influence the
correct switching of the safety
equipment and lead to the
destruction of the heater.
8
06.11.2001 13:53 Uhr
Technical Data
Max. nominal heat load:
Min. heat load:
Air throughput:
Connected load:
Operating pressure:
Nominal voltage:
Gas type:
Free of radio interference according to EG guideline 82/499 EWG
Made in Germany
5mm
E
L 1
Q1 On/Off switch
F1 Safety thermostat
M1 Fan motor
Y1 Burner valve
Y2 Thermoelectric ignition fuse
Y3 Safety solenoid valve
B1 Thermoelement
B2 Piezo ignition
B3 Ignition electrode
B4 Burner
Seite 8
30 kW (26000 kcal/h 102389 BTU)
M 1
B 1
M
Y 3
v
Q 1
Y 1
N 1
19 kW (16350 kcal/h 64846 BTU)
1000 m
1.5 kg/h (at 19 kW)
2.4 kg/h (at 30 kW) liquid gas
230 V~/50 Hz, 35 W
Propane/butane cat. 1.3
B 4
B 3
/W
B 2
Y 2
F 1
3
/h
1.5 bar