For more detailed information,
consult the manual supplied by the engine
manufacturer that accompanies each generator .
Repeated attempts at starting with
negative outcome may cause excess accumulation of
water in the exhaust system with possible serious
damage to the engine.
If it is difficult to start the engine, do not insist for too
long without first having closed the sea intake cock
[Fig. 6 Ref. 2].
Before stopping the generator it is
recommended to let it run for a few minutes without
drawing electric current, in order to allow the engine
and the alternator to cool down.
IS 18 - 21 - 24 - 27
- The low oil pressure protection does not give an
indication of the level of engine oil in the sump.
Therefore, check this level daily.
- The engine functions properly if it does not exceed
an inclination of maximum 30º for less than 3
minutes, 25º without time limit, both on the
longitudinal and the transverse axis. If the engine is
operated at a greater inclination, the risk is
insufficient lubrication or aspiration of engine oil
through the air filter.
In the event of one of the above
described protections intervening, after ascertaining
and removing the cause of the intervention, press the
“STOP” button to reset the control panel (otherwise
the signal would remain in memory preventing the
engine from starting).