DETERGENT SOLUTION

For the versions without automatic detergent dosing system, after filling the solution tank with clean water, add the liquid detergent to the tank in the concentration and manner indicated on the detergent
manufacturer's label. To prevent the formation of an excessive amount of foam that could damage the vacuum motor, use the minimum percentage of detergent required.
CAUTION: protective gloves should always be worn before handling detergents or acidic or alkaline solutions, to avoid serious injury to the hands.
ATTENTION: always use detergents whose manufacturer's label indicates their suitability for scrubbing machines. Do not use acid or alkaline products or solvents without this indication.
ATTENTION: always use low-foam detergent. To avoid the production of foam, put a minimum quantity of anti-foam liquid in the recovery tank before starting to clean. Do not use pure acids.
For versions with automatic detergent dosing system, fill the solution tank with clean water and then proceed as follows:
1.
Take the machine to the usual place for filling the solution tank.
2.
Perform the procedure for securing the machine ( see the section titled
3.
Press the recovery tank release lever (1) and turn the recovery tank into the maintenance position (Fig. 1).
4.
Disconnect the male insert (2) from the female insert (3) on the cap of the detergent canister (Fig.2).
N.B. : before pulling on the male insert, push the lever in the female insert.
5.
Grip the handle on the detergent canister (4) to remove it from the compartment in the solution tank (Fig.3).
6.
Unscrew the cap (5) of the detergent canister (Fig.4).
7.
Fill the canister with the required detergent, as indicated on the label of the machine.
CAUTION: protective gloves should always be worn before handling detergents or acidic or alkaline solutions, to avoid serious injury to the hands.
N.B.: always use low-foam detergent. To avoid the production of foam, put a minimum quantity of anti-foam liquid in the recovery tank before starting to clean. Do not use pure acids.
ATTENTION: always use detergents whose manufacturer's label indicates their suitability for scrubbing machines. Do not use acid or alkaline products or solvents without this indication.
ATTENTION: the dosing system is suitable for frequent maintenance cleaning. Acid or alkaline maintenance detergent tank be used with pH values between 4 and 10 and that do not contain: oxidising
agents, chlorine or bromine, formaldehyde, mineral solvents. The detergents used must be suitable for use with scrubbing machines. Wash the circuit with water after use if the system is not used daily. The
system can be excluded. In case of sporadic use of detergents with pH between 1-3 or 11-14, use the floor scrubbing machine in the traditional way by adding the detergent in the clean water tank and
excluding the dosing circuit.
8.
Make sure you tighten the cap (5) properly to avoid any leakage of liquid while working. Make sure the detergent suction filter (6) is correctly positioned on the bottom of the canister (Fig.5).
9.
Grip the canister handle to replace the canister in its compartment inside the solution tank.
10. Connect the male insert to the female insert in the cap of the detergent canister.
11. Rotate the recovery tank into the working position (Fig.6). Make sure that the recovery tank retainer system is correctly engaged.
2
3
1
1
2

INSERTING WATER SYSTEM FILTER

Before using the machine for the first time the water system filter needs to be reset, for shipping reasons the filter cartridge and the cap have been removed. To insert the filter cartridge in the water system filter
body proceed as follows:
1. Take the machine to the maintenance area.
2. Make sure the machine has been secured (see the section titled
CAUTION: users are advised to always wear protective gloves, to avoid the risk of serious injury to hands.
3. Close the tap's output flow, and shift the knob (1) on the left hand side of the steering column (Fig.1) downward.
4. Move to the front of the machine, insert the filter cartridge (2) in the housing on the cap (3) (Fig.2).
N.B.: The O-ring gasket in the filter cartridge should be inserted into its seat in the cap.
5. Screw on the cap (3) to the body of the detergent solution filter (4) (Fig.3).