About installation (Continued)
Installing the Projector and Screen
While installing, please place this unit and the screen perpendicular to each other. Failing
to do so may increase trapezoidal distortion. (Reference page: 34, 49)
Set Angle
As shown in the illustration, this unit can be installed
with a tilted angle, but for some areas there might be
other conditions. Moreover, depending on the angle of
installation, it may be necessary to have a hanging metal
mount and secure installation base depending on the angle
of the installation.
Area A: The range where installation is possible.
Area B: The necessary range for the installation of the
lamp attachment. Please make sure to use the
supplied lamp attachment. (Reference page: 58)
Failure to attach it might cause equipment failure.
Shift
■
Left/Right position
* 0% up/down position (center)
Approximately 34%
(maximum) of the
projected image
Lens shift correlation chart:
Left-Right Shift(%)
80%
Up-Down Shift(%)
●
Maximum Up-Down shift varies with the amount of Left-Right shift.
Likewise, maximum Left-Right shift varies with the amount of Up-
Down shift.
The values on the chart are intended to act as a guide. Use them
●
for reference during installation.
This manual downloaded from http://www.manualowl.com
Approximately 34%
(maximum) of the
projected image
0%
10%
20%
30%
66%
47%
18%
Downward slope
of 45 °
■
Up/Down position
* 0% left/right position (center)
■
Lens shift movement
range
90
80
34%
70
0%
60
50
40
30
20
10
0 10 20
Horizontal lens shift (%)
ENGLISH
Area A
Area B
Downward slope
of 45 °
Approximately 80%
(maximum) of the
projected image
Approximately 80%
(maximum) of the
projected image
Lens movability
range
30
40
19