INSTALLATION
Caution!
The cooker may only be connected
to a liquid gas cylinder or the existing
gas supply by an authorised fitter,
observing all safety rules.
Connection with a flexible steel hose
If the cooker is connected according to the
class 2 specifications, sub-class I, only flex-
ible metal hose can be used which meet
the valid national regulations. Gas feeding
connector must be G ½" threaded coupling.
Use only pipes and fittings that meet the
requirements of the valid standards. Maxi-
mum admissible length of the flexible hose
is 2000 mm.
Make sure the connection is not touching
any mobile elements which could damage
the hose.
Connection with a stable pipework
The cooker comes with a G ½" threaded
coupling.
The connection to gas supply must be done
in a manner that excludes stresses in any
point of the pipework or parts of the appliance.
Make sure you do not exceed the torque
when making the connection (maximum
torque is 20 Nm). Otherwise, the connection
may be faulty or leaks may occur.
The gas hose should not touch metal ele-
ments of the cooker back shield.
*optional
Important!
Each time you replace a reducer
carry out technical inspection of the
cooker that covers gas valves and
proper operation of the flame failure
cut-off device.
Caution!
On completion of the cooker installa-
tion, the tightness of all connections
should be checked, e.g. applying
water with soap.
Do not use fire to check tightness.
48