• ELECTRONIC BOARD
SAFETY DEVICES
• THERMOCOUPLE:
On the smoke vent, it detects temperature.
Based on the parameters set, it controls the switch-on,
working and switch-off phases.
• PRESSURE SWITCH
On the smoke extraction zone, it intervenes when negative
pressure problems are detected on the smoke circuit (e.g.:
chimney blocked).
It blocks pellet loading and causes the stove to switch off.
• SAFETY THERMOSTAT:
It activates when the temperature inside the stove is too high.
It blocks pellet loading and causes the stove to switch off.
CHARACTERSTICS
SERIAL PORT
On the serial output RS232 with a specifi c cable (code 640560)
the TSC (Technical Support Centre) can install an optional to
control switch-on and switch-off, e.g. ambient thermostat. The
serial output is found on the back of the stove.
BUFFER BATTERY
There is a buffer battery on the electronic board (type CR 2032
x 3 Volt).
Its malfunctioning is the result of normal wear (not considered a
product fault). For further references, contact the TSC (Techni-
cal Support Centre) that carried out fi rst start-up.
FUSE
on the socket with the switch placed on the rear of the stove,
there are two fuses inserted, one of which functional * and the
other spare**.
- 110
-
**
*