4. Maintenance
-
Flushing: The membrane will be flushed automatically at
-
Prefilter: If the tap water is not extremely polluted, a yearly replacement of both prefilter cartridges will be
sufficient. If the water is higher polluted, the cartridges have to be changed more often - as required.
Membrane: The membrane normally has a lifetime of several years. Afterwards, it has to be replaced.
-
Flushing valve: The flushing valve has a limited lifetime. In case of a decrease in adjusted waste water
-
flow, the valve is encrusted with calcium and can be cleaned using acid (e. g. vinegar). If the waste water
flow increases, the valve has to be replaced.
5. Failures
-
Waste water flow rate is too high:
very quickly at high degrees of water hardness. Then, the unit has to be returned for checking to the
manufacturer or dealer.
-
Waste water flow rate is too low: Check if the prefilters are blocked. If so, replace them.
-
Pure water flow is too low: Check if the waste water flow is also low and maybe change the prefilter.
-
Tap water pressure is too low: Check the high pressure pump.
-
The membrane is blocked or expired: The membrane has to be replaced. As spare parts all standard 18"-
membranes
with a
Polyamide/Polysulfone should be used. We recommend to use original Aqua Medic TFC-membranes. If you
want to use a membrane with a different capacity, you also have to change the flush valve.
-
Rejection rate is too low: Check if the sealings at the connection of the membrane are tight or if there's a
crack in the support of the membrane's housing. If so, replace the membrane.
6. Important Notes
-
Connection: Connect the reverse osmosis unit only to cold water supply. Higher temperatures increase the
pure water production but at temperatures above 40 °C, the membrane will be destroyed.
-
Stopping the unit: If you stop the unit, always close the tap water supply and pull the power plug.
-
Disconnection of the unit: If you want to disconnect the unit for a longer period than 6 weeks, you should
take the membrane out and put it in the fridge (keep it humid) or fill the unit with an adequate disinfectant
liquid. If the unit is started again, it has to run for a few hours. The water produced then has to be discarded.
7. Warranty conditions
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period,
we will repair the product for free by installing new or renewed parts. This warranty only covers material and
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. In case of
a fault with the unit during or after the warranty period, please contact your dealer. All further steps
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to
us via specialist dealers cannot be processed. AB Aqua Medic is not liable for consequential damages
resulting from the use of any of our products.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
9
Replace flush valve or check membrane's power. The unit can calcify
daily output
of 400
- Technical changes reserved – 10/2019/v5
regular intervals. The LED Flush will be lit then.
litres can be