Fitting Instructions; Speed Adjustment - S&P ARTIC-405 CN TC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1

FITTING INSTRUCTIONS

(Fig. 1)
1. Join the metal bar to the base and tighten it with the bolt.
2. Insert the motor support into the metal tube and fix it with the upper screw.
3. The foot of the base is height adjustable. To select the appropriate height, loosen the lower
fixing screw, then extend the bar upward until you obtain the desired height and tighten the
fixing screw firmly.
(Fig. 2)
1. Loosen the holding bolt on the back grill (clockwise) and the fan blade holding bolt (anti-
clockwise) from the motor shaft.
2. Mount the back protective grill on the motor head, ensuring that the 3 holes located in the
grill coincide with the three pins on the front part of the motor. Fix the grill to the motor using
the holding bolt for the back protective grill.
3. Place the fan blade on the motor shaft, adapting the slots in the central part of the fan blade
to the pins on the motor shaft and tighten the holding bolt for the fan blade.
4. Check the fan blade by turning it manually. Ensure that there is no friction with the safety
counter bolt. The fan blade must turn freely, if not, repeat the previous steps.
5. Mount the front protective grill by introducing the hook, located on the upper part of the
same, into the back protective grill. Unite the two gratings and press until they are well
joined within the plastic ring.
6. Close the security clip located on the bottom part of the front grill and tighten the screw.
USING THE FAN AND CONTROL FUNCTIONS
• After verifying that the supply voltage matches the characteristics plate, connect the device
to the power supply.
• Control the different functions either using the buttons on the fan's control panel or with the
remote control. (Fig.4).
ON / OFF
The fan always start at 1 speed and without oscillation.

SPEED ADJUSTMENT

With the speed button, you can select up to 6 different speeds.
OSCILLATION MODE
The fan has a mechanism that allows the oscillation of the column. Pressing the
button enables or disables the oscillation mode. The front indicator is lit when the
oscillation mode is enabled.
TIMER OFF
Using the control buttons on the timer, it is possible to program the fan stops auto-
matically after 1h-9h.
Operating example
By selecting this sequence, the fan will run at 5 speed and with oscilla-
tion during the hours that have been scheduled.
9

Publicidad

Tabla de contenido
loading