Descargar Imprimir esta página

EDG 3000 Manual De Instrucciones página 20

Publicidad

Idiomas disponibles

Idiomas disponibles

PROGRAMMING
Sequence:
A - Temperature 1, Temperature 2, Temperature 3
B - Velocity 1, Velocity 2, Velocity 3
C - Steady Phase 1, Steady Phase 2, Steady Phase 3.
1.Turn on the Main Switch Key (7)
2. The Display (1) will show the real furnace temperature (our example 25°C) and the LED "PROGRAM" (4)
will lit indicating that system will be ready to receive thedesired programming.
3. Press "T" key (9) until the "T1 " Led is lit. The first display digit (thousands digit) will blink
4. Press the key " " (2) until the blinking number is "0" (zero)
5. Press the
key (3) once, so blinking digit moves to the hundreds column.
6. Press the key " " until the blinking number is "3" (three).
7. Press the
key (3) once, so blinking digit moves to the tens column.
8. Press the key " " until the blinking number is "0" (zero)
9. Press the
key (3) once, so blinking digit moves to the unit column.
10.Press the key " " until the blinking number is "0" (zero)
11 .Press the key "T" once, until the "T2" Led is lit. Repeat the steps from 4 to 10
above, but substituting the values to: "0"; "9"; "5"; and "0".
12.Press the key "T" until the "T3" Led is lit. Repeat the steps from 4 to 10 above, but
substituting the values to: "0"; "8"; "5"; and "0".
13.Press the key "T".
The 3 levels temperature is programmed.
07