MAIN PARTS NAME

Hook
Inner duct cover
Outer duct cover
Exhaust pipe
Air outlet
Blower box

INSTALLATION REQUIREMENTS

1.Do not install the cooker hood where there are many doors or windows,
to avoid effecting the exhaust efficiency of the hood caused by air
convection.(Fig. 1)
2.Install the cooker hood right above the hob. The recommended
distance between the hob and the lower edge of the cooker hood show as
below. (Fig. 2)
3.To obtain optimum performance, the external conduct must not be more
than FOUR METRES long, have no more than two 90° angles and its
diameter must be at least Ø120. (Fig. 3)
4.After hanging the unit on the wall, ensure the hood is level and vertical.
5.The air outlet must not be connected to chimney flues or combustion
gas ducts. The air outlet must under no circumstances be connected to
ventilation ducts for room in which fuel-burning appliances are installed.
DVC560B
DVC560W
Fig.1
4
Hook
Inner duct cover
Outer duct cover
Exhaust pipe
Air outlet
Blower box
DVU560B/DVU560W
DVU590B/DVU590W
Fig.2
Fig.3