Electric Safety; Introduction; Processable Materials; Technical Data - WAGNER PlastMix 15 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
PlastMix 15
1.3

ELECTRIC SAFETY

The PlastMix 15 mixer is constructed according to standard EN
60204-1, with protection against water sprays and protection
against overload and power failure.
The mixer must be connected to the earthing circuit.
The power lines must be laid to prevent any possible damage.
Never place the mixer on electric power cables.
Ensure that the electrical connection is protected against the
risk of water penetration in connectors. Use exclusively con-
nectors and couplings equipped with water spray protection.
- Never use inadequate or provisional electric lines: if in doubt
consult specialist personnel for assistance.
- Repairs to the electrical circuit must be performed exclusively
by specialised personnel. Disconnect the machine from the
power supply before performing maintenance or repairs.
-Avoid contact of electric wires with movable and/or moving
parts of the machine. to avoid injury from contact with live
metal parts.
2

INTRODUCTION

2.1

PROCESSABLE MATERIALS

The continuous mixer is designed to process bagged goods.
It is suitable for the universal mixing of the following materi-
als:
Mineral thermal insulation composite system adhesives and
reinforcement
Building adhesive
Mineral textured plaster up to about K 5 mm
Lime-cement plasters
Cement plasters
Interior lime plasters
Refined concrete
Processing of other coating materials only
after consultation with WAGNER application
technology.
2.2

TECHNICAL DATA

Voltage:
Fuses:
Unit connecting line :
Gearmotor:
Water pump (accessory):
Water connection:
Waterpressure setting (min): 2.0 bar
Mixing capacity
(approximate):
Dimensions L x W x H:
Loading height:
Height of mixing tube (adju-
stable):
Maximum grain size:
Hopper capacity:
Weight:
With Water pump (acces-
sory)
Degree of protection:
Noise emission level*:
L
at 1m
PA
L
WA
* The table shows the sound pressure levels of the mixer
measured at the ear of the operator (L
emission levels in the environment (power L
according to EN ISO 3744 (2000/14/CE)
230 V ~, 50 Hz
16 A time-lag
6 m long, 3 x 2.5 mm
2
1.4 kW
0.45 kW
1/2" GK
15 l/min
1380 x 720 x 1650-950 mm
1165 mm/ 1095 mm/ 950 mm
860 mm / 790mm / 650 mm
5 mm
60 l
78 kg
85 kg
IP 56
< 65 dB (A)
88 dB (A)
at 1 m) and noise
pA
) measured
WA
GB
17

Publicidad

Tabla de contenido
loading

Tabla de contenido