Remedy In Case Of Faults - WAGNER PlastMix 15 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
PlastMix 15
9

REMEDY IN CASE OF FAULTS

PROBLEMS
Machine does not start
Thermal cutout trips on start-up Mixer is overloaded
Material consistency not cons-
tant; too hard or too fluid
The water continues to exit
from the mixing chamber when
machine is stationary
Material does not exit the off-
load port
Mix not optimal
CAUSES
Electric current
- No current delivered to connector of
site panel (fuses?)
- No power delivered to machine (de-
fective connector connection? loose
cable?)
- Main ON/OFF (thermal cutout)
switch not turned on
- Mixing chamber open (thermal ma-
gnetic switch does not engage)
- The material in the mixer has gone
hard.
- The type of material requires more
water for mixing
Water supply insufficient
- Water hose bent
- Pump inlet water filter clogged
- Pressure reducer water filter clogged
- Pressure reducer faulty
- Water supply is not sufficient (fit mi-
xer with pump)
Solenoid valve faulty
Mixing chamber clogged
- The container used for offload is too
high and does not enable the mate-
rial to flow out
- The offload port is clogged
The type of material used is not sui-
table
- Not all products on the market can
be mixed with this type of high
speed mixing system
- Mixing shaft worn
CORRECTIVE ACTION
- Check points listed alongside
- Empty mixer completely and fill with new mate-
rial.
- Increase the quantity of water delivered
- Check points listed alongside
- Please contact Wagner Service
- Check points listed alongside
- Consult the material manufacturers to check
compatibility
- Replace shaft
GB
23

Publicidad

Tabla de contenido
loading

Tabla de contenido